Mastering Circuit Breaker Failure Protection Scheme
How CBF is implemented in Substations, Power Plants & Electrical Systems
4.22 (18 reviews)

141
students
2 hours
content
Jul 2023
last update
$39.99
regular price
What you will learn
What are different types of breaker failure that can occur in power system:
Circuit Breaker Failure due to Mechanism Fail
Circuit Breaker Failure due to non-interruption of fault current
Circuit Breaker Failure due to DC control/trip supply fail
Circuit Breaker Failure due to tripping coil failure
Circuit Breaker Failure due to low DC voltage
Circuit Breaker Failure due to Aux contact failure
Circuit Breaker Failure due to Fire
Circuit Breaker Failure due to delayed tripping
Circuit Breaker Pole Discrepancy
What is Circuit Breaker Pole Discrepancy:
Single pole & three pole circuit breaker operated mechanisms
advantages of single pole tripping & reclosing
How single pole reclosing support system
What is meaning of pole discrepancy
How pole discrepancy is detected in system
Pole discrepancy circuit working
Timer circuit in pole discrepancy
Stage 1 & Stage 2 operations of pole discrepancy
Pole discrepancy during closing command & tripping command.
Re-trip and 2nd stage
What is typical time settings for Pole discrepancy
Creation of 3I0 zero sequence current during pole discrepancy condition
How Pole Discrepancy can lead to indiscriminate tripping in the network
Busbar Schemes:
Single Bus Single Breaker Scheme, Double bus single breaker scheme, one and half breaker scheme, double bus double breaker scheme, mesh breaker scheme
How to change over load from one bus to another bus without interruption, advantages of different busbar scheme
Circuit Breaker Fail Philosophy:
Circuit breaker failure protection using relay coordination at low / MV levels
What to do & protect if one breaker fail
Understand basic concept of breaker failure, if some one understand well can design and understand all CBF protection schemes & logic
CBF protection example in one and half breaker scheme, how to protect system if middle breaker fail
How to protect system if main breaker fail. CBF protection example in double bus double breaker busbar, consider the case of bus coupler & bus sectionalizer.
Circuit Breaker Failure logic block, CBF initiation function, CBF current guard, CBF Low current mode, CBF CB Aux contact input,
CBF timer, CBF stage 1 & Stage 2, CBF for Mechanical Protection not involving current, CBF protection and End fault protection
CBF Re-trip & 2nd stage faulty CB isolation from sources
CBF when Circuit Breaker is faulty
CBF and lockout function, 86 close block relay
Screenshots




Related Topics
4410512
udemy ID
11/23/2021
course created date
12/28/2021
course indexed date
Bot
course submited by